Checking OCR-Related Logs
0 min
For advanced OCR-related troubleshooting, increase the log level of the com.kron.sc.remote.desktop.impl.RdpPngRecognizer component to DEBUG. Enabling this debug mode causes Kron PAM to capture both the processed images and the extracted text, storing them under /pam/gui/logsfolder. From this directory, you can review each captured image alongside the corresponding recognized text. This allows you to verify OCR accuracy, identify mismatches, and pinpoint where the RDP auto-login process may be failing.