title: Alarm Threshold Set up
slug: kronpam-reference-guide-3-8-0/alarm-threshold-set-up
description: This document provides valuable insights into configuring alarm thresholds for various severity levels such as CPU, memory, storage, license count, license expiry, and latency. Learn how you can easily edit, update, and save these customizable values usin
docTags: 
createdAt: 2022-08-02T17:44:08.000Z
---

In this tab, the following alarm thresholds can be set for each severity level (minor, major, critical):

-  CPU (in percentage)
-  Memory (in percentage)
-  Storage (in percentage)
-  License Count (in percentage)
-  License Expiry (in days)
-  Latency (in milliseconds)
- Unreachable Within (in minutes)
  - The **Unreachable Within** parameter specifies the duration of communication disruption between Kron PAM servers in an Active-Active redundancy setup. If this threshold is exceeded, the other Kron PAM server is marked as unreachable.

When opening the screen, the previously defined values are automatically displayed. All thresholds can be edited and updated by the user and saved using the **Save** button.

![](https://api.archbee.com/api/optimize/g9cApVza9NIhSh0pjZYtA/4dopaDgLNmnkMqk80X2PW_image.png "Alarm Thresholds")

:::hint{type="warning"}
For storage alarms to function correctly, proper mapping between alarm definitions and disk usage monitoring is required.

Disk usage values are collected by the pam-diag.sh script, based on mount points defined in the pam-diag.config file. The relevant parameters in this file are:

·         OSMountPoint=/

·         AppMountPoint=/pam

·         DataMountPoint=/pam/PostgreSQL11

The script reads these mount points and periodically calculates disk usage by executing the df -Pk command. Collected data is written to the sc\_diagnostics table using the corresponding fields:

- os\_disk\_usage
- app\_disk\_usage
- data\_disk\_usage

When defining storage alarms in the **Alarm Parameters** tab, each alarm type (e.g., OS, Application, Data) must be associated with a distinct mount point. If multiple mount definitions refer to the same physical disk, identical values will be recorded, and alarm behavior may overlap.

To ensure reliable monitoring, each logical disk to be monitored should be mounted as a separate physical volume and referenced accordingly in the configuration file.
:::