Configuration for SMS over SMPP
To use the Kron PAM connection and command approval workflows via SMS using the SMPP connection:
- Navigate to Administration > System Config Man.
- Set the value of the command.approval.sms.smpp.body and connection.approval.sms.smpp.body parameters and click Save.
connection.approval.sms.smpp.body: SMS template for connection approvals. It should be defined in the template below. Parameters with %...% should be kept.
Your approval is requested by %requester_username%. You can manage the approval request by using Policy Control / Approval Management. Approval ID is %approval_id%
The available keywords to be used in these templates are: %approval_id%, %approval_keyword%, %rejection_keyword%, %requester_username%, %requested_host%, %selected_username%
command.approval.sms.smpp.body: SMS template for command approvals. It should be defined in the template below. Parameters with %...% should be kept.
Your approval is requested by %requester_username%. You can manage the approval request by using Policy Control / Approval Management. Approval ID is %approval_id%.
The available keywords to be used in these templates are: %approval_id%, %approval_keyword%, %rejection_keyword%, %requester_username%, %requested_host%, %command%
The user can send an SMS response in the following format: keyword_response approval_id Example: APPROVE Gwt674h